hot line 4008871248 Chinese English

   
  TEL:0551-65314006
     0551-65314706
  FAX:0551-65314136
  CODE:230088
  E-MAIL:ahmodern@ahmodern.com
  ADD:The high-tech zone science avenue, NO 109 Hefei, anhui, China
  home > solution
Tianjin television station broadcast safety monitoring system
2012-10-22 点击:2177 次

Description of project: 

Broadcast according to the monitoring station are put forward in the safety monitoring system design requirements, the system includes a complete signal monitoring, automatic alarm and fault event log, etc. All equipment shall have broadcast technology indicators, to ensure safety broadcast 24 hours a day. Signal monitoring system is the digital processing way, overall architecture USES the TS over IP technology, source in the signal processing process does not have any digital to analog conversion process. Can effectively block of digital TV, canceled, black field anomalies such as monitoring and early warning, analysis and monitoring in real time. 

Implementation for digital television broadcast quality regulation, offer excellent quality of the digital TV service, will create channel safety monitoring system, real-time monitoring of signal source, and at the same time can be done to the abnormal signal real time alarm, send signal monitoring system, through the network of television 30 the SDI standard definition of signal with 2 road the hd SDI signal quality monitoring, and can automatically audible and visible alarm, abnormal information display, etc. 

 

Second, the demand analysis: 

Set up 30 sign qing SDI signal and two-way hd SDI signal monitoring alarm system. 

Monitoring audio content mainly includes: 

Low video: static frame, black, the color bar, the color field, video interruptions, precision: 1 frame 

Low audio: voice interrupted, audio, audio is too high, too low accuracy: 1 SEC 

Low monitoring host requirement timely response to the alarm sound and light alarm and software in parallel; 

alarm system with high accuracy, response time is small, all kinds of alarm parameter threshold can be set up; 

signal monitoring frame size can be set up, can be modified in accordance with the requirements of the air; 

monitoring host requirements go IP signal, software can record all the failure information and query by date, channel failure; 

when software requirements set user permissions 

 

3, system topology: 

 

System integration solutions with low density, standard definition monitoring host can monitor each two road signs of black SDI signal, high-definition monitor host can monitor each hd SDI signal all the way, when a monitoring device failure occurs (such as audio interrupts, too low, video, static frame and black field failure), will only affect the monitoring of the channel, channel fault would not spread to other monitoring, which can effectively reduce the risks of excessive concentration diffusivity. 

All systems through the switches to connect into 1000 m Ethernet, monitoring host and switches via 1000 m network connection, other devices connected to the switch through the 100 m / 1000 m so, real-time high speed data interaction can be performed. 

 

Four, the structure of the system features: 

All IP structure online operation, simple and efficient, convenient extension, HDTV and high precision monitoring. 

Low FPGA + DSP digital integrated circuit and subtract algorithm is adopted to form core monitoring module, high speed and high precision with high accuracy. 

The embedded structure, no PC, no crash, virus. 

Various independent distributed monitoring alarm way, once the failure occurs, will not affect other channels, which can effectively reduce the risks of excessive concentration diffusivity. 

Second-ranking distributed monitoring system will be independent from the one-piece all equipments, antivirus, compatibility of the system. 

Users can build a PC type, completely out of the PC software and hardware of the relatively weak problem, make the system run more stable.